An EWS1 form is a standard process created by RICS that allows a building owner to confirm to lenders and valuers that the external wall system of a residential building has been assessed for safety. A suitable expert carries out a fire risk appraisal of the external wall system before signing the form. The document then covers the entire building for a period of five years.

The EWS1 form is designed for valuation and lending purposes only. It is not a life safety certificate and it does not replace a standard life safety fire risk assessment for the building. You do not need a separate form for an individual flat, because each block receives one form that applies to all the flats inside it.

The form is not a legal requirement to sell a property. Without one, a buyer may simply struggle to get a mortgage if their lender decides the building needs an assessment. You can read the official guidance in the RICS FAQs.

Why mortgage valuers ask for one

When you buy or remortgage a flat, the mortgage lender needs to know that the property is worth the money they are lending. The lender sends a valuer to inspect the property and report back. If the valuer sees certain types of cladding or balconies, they follow their lender instructions and ask for an EWS1 form.

The form gives the lender confidence that a qualified professional has checked the external walls. It tells them whether the materials pose a fire risk and whether expensive remedial works are needed. If works are needed, RICS says a valuation will only be possible once there is clarity on the cost of the work and a timeline for it to be completed.

Valuers use the EWS1 process to understand the financial risk attached to the building. You can read more about how lenders assess property values in our guide to mortgage valuation explained.

Which buildings may need one

Not every block of flats needs an EWS1 form. Valuers follow criteria set out by RICS to decide if an assessment is necessary. The decision is based on the height of the building and the materials visible on the outside.

The RICS criteria look at visible cladding, curtain wall glazing and certain balcony configurations. They set different thresholds depending on how tall the building is. The rules are divided into buildings over six storeys, buildings of five or six storeys and buildings of four storeys or fewer.

Valuers look for the following features when deciding if a building needs an assessment:

  • The total height of the building
  • The presence of visible cladding
  • The use of curtain wall glazing
  • Certain balcony configurations

Buildings under 11 metres are generally less likely to need costly fire safety works. If work is needed on these lower buildings, cheaper measures like fire alarms are often more appropriate.

The new RICS standard from 1 November 2026

RICS published the second edition of its secured lending valuation standard on 12 May 2026. This updated standard takes effect on 1 November 2026 and provides strict guidance on when a valuer should ask for an assessment.

Under the new rules, an EWS1 form should only be requested where there is a clear rationale based on the building height and materials. The standard also states that buyers and their legal advisers should seek the building fire risk assessment before purchasing a flat. You can read the details in the RICS updated standard.

The new standard introduces flexibility around the documentation a lender can accept. In some circumstances, an executive summary or summary report of a PAS 9980 fire risk appraisal of external walls can be relied on instead of an EWS1 form.

This alternative is only acceptable if the summary report gives a clear outcome on whether remedial works are required. It must also be signed by a suitably qualified professional. This helps to prevent delays when a full EWS1 form is not immediately available.

What the Option A and Option B ratings mean

When an expert completes an EWS1 form, they assign the building a rating based on the materials found in the external walls. The form has two main options, known as Option A and Option B.

Option A means the external wall materials are unlikely to support combustion.

Option B means that combustible materials are present in the external walls. This option is split into two sub-ratings that tell the lender exactly what needs to happen next. A B1 rating means the fire risk is sufficiently low that no remedial works are required. A B2 rating means the fire risk is high enough that remedial works are required.

With a B2 rating, RICS says the remedial works need to be carried out before a mortgage can proceed, unless the lender agrees otherwise. The section on remediation below explains when many lenders have agreed to lend.

Who can carry out the assessment and sign the form

The EWS1 form must be completed after a fire risk appraisal of external walls has been done. It must be signed by a fully qualified, competent member of a relevant professional body. The signatory must have the expertise to assess the wall materials, cavity barriers and fire stopping in line with the PAS 9980 standard.

The type of professional required depends on the height and complexity of the building. Since January 2021, RICS has trained chartered building surveyors and chartered building control surveyors to assess low to medium rise residential buildings. These are defined as buildings below 18 metres or seven storeys.

Buildings of 18 metres or seven storeys or more require a different level of qualification. High risk buildings that need specialist testing also fall into this higher category. For these buildings, the form must be signed by a qualified fire safety engineer who holds chartered or incorporated status.

When arranging an inspection of the flat itself, you might wonder whether to instruct a Level 2 or Level 3 survey, but remember the EWS1 is a separate process handled entirely by the building owner.

How long the form lasts and checking it is valid

Once signed, an EWS1 form is valid for five years and covers the entire building. The form was updated on 16 March 2022 to reflect the PAS 9980:2022 standard. It is now an electronic document with version control.

Earlier versions of the form remain valid for their five year lifespan, but you should always check individual lender policy. In April 2025, UK Finance and the Building Societies Association updated their industry statements on cladding. This update deals specifically with EWS1 forms that are more than five years old and forms signed by an invalid signatory.

Always check the date on the form and the credentials of the person who signed it. RICS suggests checking the signatory with the professional concerned and with their professional body, and your conveyancer can check the form against your lender's requirements.

If your building needs remediation work

If a building receives a B2 rating, it means remedial works are required to make the external walls safe. The Building Safety Act 2022 introduced leaseholder protections in England to limit what qualifying leaseholders can be asked to pay. These protections came into force on 28 June 2022 for leaseholders in buildings above 11 metres or five storeys with historical safety defects.

Qualifying leaseholders are protected from all cladding system remediation costs. Any contribution you must make for non-cladding defects and interim measures is capped and spread over 10 years.

You qualify for these protections if you meet all of the following conditions:

  • Your lease is a long lease of over 21 years for a single dwelling
  • Your building is above 11 metres or at least five storeys high
  • You pay a service charge to the building owner
  • Your lease was granted before 14 February 2022
  • The dwelling was your only or main home, or you owned no more than three UK dwellings

You must complete a deed of certificate and send it to your building owner to prove you qualify. Some qualifying leaseholders are exempt from all historical safety remediation costs. This applies if your property was valued at less than £325,000 in Greater London, or £175,000 elsewhere in England, on 14 February 2022. It also applies if your building owner had a group net worth of more than £2 million per relevant building on that date.

Many mortgage lenders have agreed to lend on mid and high-rise buildings with fire safety problems. They will do this as long as the issues are being fixed by the developer or through a government funded scheme, or if the leaseholder has completed a deed of certificate. You can read more about the leaseholder protections on GOV.UK.

Common questions

What is the difference between an EWS1 certificate and a FRAEW?

A FRAEW is a fire risk appraisal of external walls, which is the detailed technical assessment of the building. The EWS1 form is the standard summary document produced after the FRAEW is finished. Lenders use the EWS1 form to quickly understand the result of the appraisal.

Is an EWS1 required for buildings under 18m?

Yes, an EWS1 form can be required for buildings under 18 metres. Valuers use RICS criteria that set different thresholds for buildings over six storeys, buildings of five or six storeys and buildings of four storeys or fewer. Buildings under 11 metres are less likely to need costly works, but a lender may still ask for an assessment based on visible materials.

Does the EWS1 process apply in Wales and Scotland?

The EWS1 process applies equally in Wales. In Scotland, the rules are slightly different because separate EWS1 forms can sometimes be required flat by flat. The Scottish Government also operates a Single Building Assessment scheme for addressing cladding issues.

Who pays for the EWS1 survey?

The EWS1 process is for the building owner to undertake, so the building owner or managing agent commissions it, not the individual flat owner. Whether any of the cost is passed on to leaseholders depends on the lease and the protections that apply, so ask your conveyancer.

What buyers and sellers should do next

The EWS1 process is entirely the responsibility of the building owner or managing agent. As a buyer or seller, you cannot instruct a surveyor to produce an EWS1 form for your individual flat.

Buyers and sellers dealing with a flat in a block with cladding or balconies should take action early to avoid delays. Follow these steps to keep your transaction moving:

  • Ask the building owner or managing agent if an EWS1 form or PAS 9980 summary already exists
  • Check the date on the document to ensure it is within its five year validity period
  • Ask your conveyancer to review the building fire risk assessment before you exchange contracts
  • Ask your conveyancer to check whether the seller has completed a deed of certificate if the building needs remedial works

If the building owner refuses to carry out the assessment, the local council can advise you. The matter should also be referred to the fire and rescue service. Always involve your conveyancer as early as possible so they can check the paperwork meets the lender requirements.

Find a surveyor near you

Understanding external wall systems and leaseholder protections is a complex part of buying a flat. While the building owner handles the EWS1 process, you will still need an expert to inspect the inside of the property and report on its general condition. To get started with your own property inspection, find a surveyor near you to discuss the right level of survey for your new home.

Find a top rated surveyor near you

1,519 surveyors across the UK, each ranked on their Google rating and the number of reviews behind it. Start with your county:

All counties and towns · The UK Top 100 surveyors

Richard Langley
Written by

Richard is a writer and editor for Top Rated Surveyors, covering house surveys and buying a home. When he's not writing guides, he plays the guitar badly but often.

Looking for a trusted surveyor? Browse our verified listings.

Find a Surveyor